A Simple Key For Dp50rb Unveiled
A Simple Key For Dp50rb Unveiled
Blog Article
Assist 4D probe; acknowledge the probe by way of the ID code; change the 4D drive signal by using the electrical relay to generate the 4D probe function Typically. four.two.2 Principal board The leading board might be divided into two areas: entrance-finish of the most crucial board and again-conclusion of the principle board.
Utmost 4 instances tasking for just one transmitted beam, leading to exceptional time resolution and better body fee.
Take note: About the watch, the brightness adjustment will come ahead of contrast. Immediately after readjusting the watch’s contrast and brightness, change all preset and peripheral options.
Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.
Slice off cable ties connecting the primary unit around the Exhibit by diagonal chopping pliers, then pull out the corresponding cable plugs.
Mindray’s new era of black & white ultrasound technique, DP-fifty Qualified, is provided with Highly developed imaging systems letting deeper penetration and a lot quicker image acquisition with better resolution.
The chapter provides the tactic to validate primary operate and efficiency of solution. This can be only utilized for reference, not preventive execution. Perform examining and screening of the element shall be performed by Mindray assistance engineers and also the person collectively. Page sixty six: Common Exam
Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi depth mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.
Permits usage of various scanned angles to variety a single image, causing Increased contrast resolution and improved visualization
five.two.three Geometric positioning precision Longitudinal geometric positioning accuracy Examination Action: Do adjustments as how in tests the maximum depth. Document the space by 20mm Just about every segment within the longitudinal targets line using the measurement caliper; Choose the worth with the greatest error (to 20mm), determine the precision using the formulation underneath The measurement caliper must be positioned in the higher fringe of the focus on, NOTE:... Web site seventy nine Transverse geometric positioning precision Examination Move: Protect the scan surface area in the phantom with drinking water or pair gel, gently Get hold of the probe Together with the scan surface area Alter the depth, creating the transverse targets to generally be shown during the image. Alter the main focus position to generally be posited beside the transverse targets (the conventional is not really distinct) Alter parameters like achieve, TGC, generating Every single transverse targets for being Obviously exhibited. Page eighty five.5.two.4 Blackout Area Test Move: Address the scan floor in the phantom with h2o or pair gel, Carefully Call the probe Along with the scan surface Change the depth at a lower price, and set the main focus at the closest place to the scan surface area. Reduce the value of parameters like AP, Achieve until eventually the background noise just might be found. Web page 81: Application Enhance And Routine maintenance
Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan Dp50rb kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.
Observe: Right before uploading the log, be sure the ultrasound program has been connected to network, usually, the system could warn “could not connect to server” The server (smtp.
Take note: In advance of inserting the connector to the probe port, inspect the connector pin. In the event the pin is bent, do not make use of the probe until eventually it has been inspected / repaired / changed. Installing Peripherals For that designs of your supported peripherals, remember to make reference to “two.
Your tool for deeper biopsy: allowing for adjustments on the scan line to get superior visibility in the needle, nerves and smaller vessels, guaranteeing the continuity of all information.
A wise new condition, Improved mobility and handy operation make DP-fifty well suited for all clinical configurations.